The margin line is the line on the prep where the restoration ends. In 3Shape Dental System, the die interface is built from that line. So is the lab model, if you make one. This post covers how Dental System handles the line, based on 3Shape's own articles and release notes. It then covers why the margin has to be clear on the scan when you send a crown or bridge to an outside designer, and what to send with it.

It is written for lab owners and CAD/CAM technicians. It covers design software and scan files, not clinical decisions. Some of the 3Shape articles quoted here date from 2013 and 2014, so the screens in your version may look different.

1. One margin line for the whole workflow

In 2013, 3Shape described the digital impression workflow in Dental System 2014. The user starts by modeling the crown and, if needed, moves on to the lab model in Model Builder. Scan preparation is part of the design workflow, and the margin line is defined only once for the whole workflow. For the model side, see 3Shape Model Builder: What It Does for Dental Labs.

Current Dental System release notes name a Margin Line step. A 2023 3Shape support article describes creating the margin line on the Die Interface step for crown or inlay restorations.

A coping and a crown on the same tooth share that line. A 3Shape support article from 2024, updated in 2026, says Dental Designer does not currently support separate margin lines for a coping and a crown on the same tooth in a single order. 3Shape says separate lines are under consideration for a future version. Its workaround puts the coping and the crown in separate orders.

2. Drawing, rebuilding and editing the line

An incoming case may already have a line on it. 3Shape's 2014 guide to model-free crowns notes that the dentist may have set a margin line. The guide calls it good practice for the lab to check that line before designing and milling the crown. For the three checks from the same guide, see Model-Free Crowns: Three Checks 3Shape Recommends.

Dental System has a manual and an automatic way to redo a line. A 2024 3Shape support article on the segmentation step points to the Edit Lines tool in the bottom-left panel. Draw Line redraws the line by hand, one tooth at a time. "Clear current tooth spline and rebuild" redraws it automatically after you click the occlusal area of the tooth.

Recent release notes list changes to this step. Dental System 25.1.0 (September 2025) corrected margin line generation for cases with the die scanned in the model. Dental System 25.2.0 (December 2025) improved the user experience for margin line detection. It also fixed an error that had blocked margin line placement in the Margin Line step.

Dental System 2025 added AI margin lines to the copy denture workflow. The release notes say the system detects and draws the lines from tooth anatomy and still allows manual refinements. For the rest of that release, see 3Shape Dental System 2025: What Is New for Dental Labs.

3. Why the margin has to be clear on the scan

Every tool above works on the scan you have. If the margin area was not captured, there is nothing for the line to follow.

3Shape's 2014 guide suggests viewing the impression with and without colors when you set the margin line. The two views bring out different parts of the margin area. The guide adds that you can use HD photos if the dentist included them with the digital impression. The Dental System 2014 release in January 2014 listed HD photos from 3Shape's intraoral scanner as a way to determine the margin line, with detailed images of key areas.

Holes cause a specific problem. A 2023 3Shape support article says that if the margin line crosses a hole in the scan, Dental System cannot generate the die interface model. It gives two fixes. Redraw the line so it does not cross the hole, or close the hole with the Sculpt toolkit before drawing the line again.

Another 3Shape article covers an error in the segmentation step. It says the cause most often involves poor scan quality, or design errors from incorrect margin lines or trimming. It suggests the Refine Scan tool in the Prepare step, which can remove scan artifacts, close holes and improve scan borders. As a last resort, the article says it may be necessary to ask the customer to rescan.

4. Sending a crown or bridge to an outside designer

A designer outside your lab sets the margin line from the files you send. SubDesignCenter asks for the prep, opposing and bite scans, plus a work ticket that names the material.

If part of the margin is hard to see on the scan, write that on the ticket. What happens next follows your lab's settings: some labs ask us to design first and report the area, others ask us to confirm with them before we design. HD or intraoral photos from the clinic can go along as a reference. Our guide to outsourcing dental CAD design to Korea lists it with other details worth noting. If the case has a coping and a crown on the same tooth, note that too, since Dental Designer gives both one shared margin line in a single order.

Put your Dental System version on the ticket as well. SubDesignCenter delivers the 3Shape design files in an editable form, and whether you can open and edit them can depend on your version. SubDesignCenter keeps your contact strength, occlusal clearance, cement gap and minimum thickness on file and applies them to your lab's cases. For what those values control, see 3Shape material settings and the cement gap.

When the design comes back, check that the margin follows the prep line on the scan all the way around. That check is on the list in our guide to three free test cases.

SubDesignCenter designs crowns and bridges in 3Shape for dental labs and clinics worldwide. For everything else that goes with a case, see the case prep checklist. Need a ticket template? Our free dental lab Rx form runs in your browser and saves as a PDF.

Checklist

  • Prep, opposing and bite scans in the case
  • Margin area viewed on the scan with and without color
  • Holes near the margin found before the line is drawn
  • HD or intraoral photos from the dentist sent along as a reference
  • Hard-to-see margin areas, and any coping and crown on one tooth, noted on the work ticket
  • Material and Dental System version on the work ticket
  • Returned design checked: the margin follows the prep line all the way around

Try it on three cases

New labs can send SubDesignCenter three free test cases: crowns, or bridges of up to 3 units, including implant bridges. For what to agree before the first case, see how to run three free test cases for 3Shape crown design outsourcing. To see prices, open the price list on our pricing page. Questions about your workflow? Reach us through the contact section on our site.

Questions

What is the margin line in 3Shape Dental System?

It is the line on the prep where the restoration ends. Dental System builds the die interface from it. 3Shape's description of Dental System 2014 says the line is defined once for the whole workflow, crown and lab model included.

Can Dental System draw the margin line automatically?

A 3Shape support article describes both ways: an automatic rebuild of a tooth's line, and a Draw Line tool for drawing it by hand. In Dental System 2025, AI detects and draws margin lines in the copy denture workflow, and manual refinements are still possible. 3Shape's 2014 guide calls it good practice for the lab to check the line before designing and milling.

What should I send so an outside designer can set the margin?

Send the prep, opposing and bite scans, plus a work ticket that names the material. If part of the margin is hard to see on the scan, write that on the ticket. HD or intraoral photos from the clinic can go along as a reference.