Home / News / 3Shape Material Settings and the Cement Gap: Why Your Design Partner Asks for Your Values
News

3Shape Material Settings and the Cement Gap: Why Your Design Partner Asks for Your Values

Send a crown to an outside designer and one of the first questions back is about your settings. Cement gap, minimum thickness, contact strength and occlusal clearance all shape the finished design. This post explains what each value controls, what 3Shape's own articles say about tying them to your mill and material, and what to send so a design made outside your lab matches the values you use in-house.

It is written for lab owners and CAD/CAM technicians. It covers design settings, not clinical decisions. The 3Shape points come from 3Shape's news articles, support pages and release notes. Some of those articles date from 2013 to 2015, so menus in your version may look different.

1. The material is chosen per order

In 3Shape's 2014 guide to model-free crowns, the material is picked when the order is created: "Here you select the material of the crown." A 2013 3Shape tip on order-form defaults lists the restoration settings you can save as a default for an order button: material, color, type, manufacturer and manufacturing process.

Each material is then edited on its own. A 2015 3Shape article describes opening the Dental System control panel, selecting Materials and choosing a single material to edit.

2. What the four values control

The definitions below are general lab terms, not 3Shape menu names.

  • Cement gap. The space a design leaves between the inside of the restoration and the prep, for the cement. It sets the internal fit.
  • Minimum thickness. The thinnest wall the design may have in a given material. Dental System release notes describe an "Enforce wall thickness" feature on the finalize step, and thickness maps that "now update in real time during sculpting."
  • Contact strength. How firmly the restoration meets the neighboring teeth. 3Shape's 2014 guide says to "design and control the crown in relation to your mesial and distal contact points," and adds that you "can also use the distance map to evaluate" them.
  • Occlusal clearance. The space between the restoration and the opposing teeth. A recent release note says the "Precise distance to antagonist" tool now works "for all crown-related indications, ensuring anatomy is cut to the antagonist as expected."

3. Why the right value depends on your mill and material

3Shape's 2014 guide is direct about the cement gap: "You will need to tune the cement-gap parameters to your specific milling machine and material."

Once a lab has found its setting, the guide says it can rely on that setting for every case milled on the same machine and in the same material. The guide adds that you "will need to test again if you invest in a new machine or use another material."

For the test steps 3Shape describes for crowns milled without a model, see Model-Free Crowns: Three Checks 3Shape Recommends.

4. Where material values come from

3Shape's support page says the export and import of material settings "provides an easy exchange of materials between the lab and the manufacturer." The values in a material can come from either side.

When exporting, the sender can tick "Lock exported materials" so the recipient cannot change the settings. From Dental System 2017, the sender also picks the Dental System version the materials are exported for.

5. Why a design partner asks for your values

A scan shows the prep and the bite. It does not show the cement gap you tuned for your mill, or the minimum thickness you hold for each material. A designer outside your lab needs those numbers from you.

SubDesignCenter keeps each lab's design preferences on file (contact strength, occlusal clearance, cement gap and minimum thickness) and applies them to that lab's cases. Designs are prepared for the material named on your work ticket. If your lab uses different values for different materials or mills, we keep them separately. You can also send your 3Shape material settings file (.dme): we design with that material, and check whether the same material is already set up.

SubDesignCenter delivers the 3Shape design files in an editable form, along with production-ready files for your mill or printer. Whether you can open and edit them can depend on your Dental System version, so put your version on the work ticket.

If you retune after a new mill or material, send the new values. SubDesignCenter designs crowns and bridges in 3Shape for dental labs and clinics worldwide. For everything else that goes with a case, see the case prep checklist. Need a ticket template? Our free dental lab Rx form runs in your browser and saves as a PDF.

Checklist

  • Material named on every work ticket
  • Cement gap written down for each mill and material you use
  • Minimum thickness written down for each material
  • Contact strength and occlusal clearance written down
  • Values retested after a new mill or material, and the new values sent to your design partner
  • Dental System version on the work ticket

Try it on three cases

New labs can send SubDesignCenter three free test cases: crowns, or bridges of up to 3 units, including implant bridges. For what to agree before the first case, see how to run three free test cases for 3Shape crown design outsourcing. To see prices, open the price list on our pricing page. Questions about your workflow? Reach us through the contact section on our site.

Questions

What is the cement gap in a 3Shape crown design?

It is the space a design leaves between the inside of the restoration and the prep, for the cement. 3Shape's 2014 guide says to tune the cement-gap parameters to your specific milling machine and material.

Why does my design partner ask for my cement gap and minimum thickness?

The values depend on your mill and material, and a partner cannot read them from the scans. SubDesignCenter keeps each lab's contact strength, occlusal clearance, cement gap and minimum thickness on file and applies them to that lab's cases. Values that differ by material or mill are kept separately.

Do I need to send new values after changing my mill or material?

3Shape's 2014 guide says you will need to test again after a new machine or another material. When the tested values change, send the new ones to your design partner.

3Shape and Dental System are trademarks of 3Shape A/S. SubDesignCenter is an independent design service and is not endorsed by 3Shape A/S.

Send a test case.

Your first three test cases (crowns, or bridges of up to 3 units, including implant bridges) are free. Tell us how your lab works and we'll set up a case exchange that fits it.

Start a case consultation →