3Shape calls implant bridges one of the most difficult indications to design, and it has reworked the implant bridge workflow in 3Shape Dental System over the past few years. This post covers what that workflow does, what it changes for a lab, and what to send when you outsource an implant bridge design to SubDesignCenter.
It is written for lab owners and CAD/CAM technicians. It covers files and communication between labs and design services, not clinical decisions. Menu names and steps can differ by software version, so check 3Shape's support pages for your version.
What the implant bridge workflow does
3Shape walked through the workflow in an April 2024 post, Dental design software deep dive: the Implant Bridge workflow.
- Layers, in order. The first step adjusts the crowns in the arch. Then the connectors and/or gingiva are built, and the bridge is combined into one piece. All emergence profiles are adjusted at the end, in a single step. In earlier versions, the emergence profiles sat in the middle of the workflow.
- Smile Composer. Teeth are no longer connected to the implants at this step. 3Shape says this makes the arch easier to set up, and makes implants placed between or outside the intended restorations easier to handle.
- Gingiva as the second step. The workflow uses the gingiva module from the denture design workflow. You can adjust its predefined settings and make edits with the sculpt tools.
- Bridge shape. You can build the top cap and adjust it to the anatomical shape of the tooth. Uncheck the anatomical top cap option and it resembles a standard abutment. A cut back option is also available.
- Emergence profiles last. This step was moved to the end so the implant openings are not changed in earlier steps. All emergence profiles are handled in one step.
- Screw holes. Once the design is finished, you can place the screw openings on the lingual or palatal side of the bridge.
- Sculpt tools and extra scans. Sculpt tools are available at every step, and you can add an additional scan, such as a face scan.
- Changing an earlier step. The latest version caches each step. If you decide mid-design to remove a premolar, you no longer have to start over. 3Shape says this is now the default.
- Scan checks. Upper and lower jaw scanrefine steps analyze the scans and show issues before you start. 3Shape says the software can usually repair them with a click.
- License. 3Shape lists implant bars and bridges among the design indications in its add-on modules for Dental System (3Shape CAD Points). Check with your reseller which modules your package includes.
Recent changes in Dental System
From 3Shape's Dental System release notes, which call emergence profiles "exit profiles":
- Dental System 2024 (24.1.0, November 2024). A new spline edit mode for implant bridge exit profiles. The scan body used during alignment now shows in the design, instead of the scan body from the library.
- 25.2.0 (December 2025). Blank positioning for implant bridges, which 3Shape describes as a way to ensure fit validation during design. Improved stability for implant bridges with cantilever pontics.
- 25.3.0 (April 2026). A new option to protect the exit profile of abutments, so its shape is kept when it connects to anatomy or gingiva. Corrected grading on the Thickness map around screw holes for implant bridges with gingiva.
- 25.4.0 (August 2026). A lingual band option for frame implant bridges without gingiva. Improved spline connection control for exit profiles in implant bridge designs, including gingiva workflows.
- Implant Studio 2026.1 (December 2025). 3Shape says Implant Studio now supports multi-unit abutment (MUA) planning. Restorative components can then be designed in Dental System from the implant and MUA plan.
What it changes for a lab
- One layer at a time. You finish the tooth setup, then the gingiva, then the emergence profiles. Each part is handled on its own and then combined.
- Implant openings stay as they are. Because emergence profiles come last, earlier steps do not change the openings. 3Shape says this removes many intermediate operations.
- A full view at the end. All emergence profiles are adjusted in one step, with the whole design in view.
- Fewer restarts. Cached steps let you change an earlier decision without starting the case over.
- The same steps across indications. 3Shape says it wants technicians to follow the same steps and use the same tools, from a single crown to a full mouth implant bridge.
- Scan problems show up first. 3Shape traces many design errors to the incoming scan data, especially third-party intraoral scans. The scanrefine steps show those issues before design starts.
- Lighter libraries. 3Shape says too many material and implant library files can slow the software down. It recommends removing implant systems or abutment kits you do not use, and backing up your libraries regularly.
How labs send implant bridge cases to SubDesignCenter
SubDesignCenter designs implant-supported bridges in 3Shape for dental labs and clinics worldwide.
- Get in touch first. Reach us through the contact section on our site. We set up the case exchange that fits your lab when we start working together. Labs on 3Shape Communicate can also send that way; see 3Shape Communicate case sharing.
- Send the case. Send a scan with the scan bodies captured, plus a work ticket that names the implant system and your design preferences. Scans can come from any intraoral or desktop scanner as STL, PLY or OBJ files. SubDesignCenter works from the implant libraries available in 3Shape. For what to include with an implant case, see our custom abutment design checklist.
- Keep patient details to a minimum. Put the patient's first name and your lab's case number on the ticket, and leave out last names, dates of birth and contact details. Need a ticket template? Our free crown, bridge and implant Rx form runs in your browser and saves as a PDF.
- Send your preferences once. Contact strength, occlusal clearance, cement gap and minimum thickness. SubDesignCenter keeps them on file and applies them to your lab's cases.
- Review and approve. Every case goes through a review step before delivery. Request refinements and the designer adjusts. A case is not finished until your lab approves it. Every case also includes a conversation with the designer about material choice, design decisions and how the design will mill or print.
- Receive the file. You receive a production-ready design file, prepared for your mill or printer. Standard turnaround is 2 business days. Cases you send in your evening are designed during our working day in Korea, so work starts while your lab is closed.
For full-arch cases, see our All-on-X design service and how to send an All-on-X case for design.
Try it on three cases
New labs can send SubDesignCenter three free test cases: crowns, or bridges of up to 3 units, including implant bridges. To plan the test, see how to run three free test cases.
Checklist
- Dental System version and implant bridge license confirmed with your reseller
- Unused implant systems and abutment kits cleaned up, libraries backed up
- Scan with the scan bodies captured, as STL, PLY or OBJ files
- Work ticket naming the implant system and your design preferences
- Patient first name and lab case number only
- Design preferences sent once and confirmed on file
- Review and approval steps agreed
- Full-arch cases sent to the All-on-X design service
If you have questions about your workflow, reach us through the contact section on our site.