A full-arch All-on-X case is not designed in one pass. It moves through stages, from a Diagnostic design to the final prosthesis design, and each stage needs its own files and its own approval. Some cases also bring data from more than an intraoral scanner: a face scan, photogrammetry data, or desktop scans of models and an existing denture. Others have no intraoral scan at all.
This guide covers four things: what to agree before the first scan, how to send data from devices other than an intraoral scanner, what to send with or without an intraoral scan, and how the stages run. It is written for lab owners and CAD/CAM technicians. It covers files and communication between labs and design services, not clinical decisions.
Before the first scan: agree on the plan
At SubDesignCenter, crown and bridge cases run on one standard turnaround of 2 business days. All-on-X does not. All-on-X stages follow a schedule agreed for each case. Settle these points before you send anything:
- Which stages? Agree which stages your partner designs. SubDesignCenter's default plan has four stages, described below.
- When does each stage come back? Put the date for each stage in writing.
- What comes back at each stage? SubDesignCenter returns production-ready design files prepared for your mill or printer.
- What is the final material? Name it at the start, together with your mill or printer.
- Which devices captured the data? List them: intraoral scanner, face scanner, photogrammetry system, desktop scanner.
Send your design preferences once: contact strength, occlusal clearance, cement gap and minimum thickness. SubDesignCenter keeps them on file and applies them to your lab's cases.
Every SubDesignCenter case also includes a conversation with the designer about material choice, design decisions and how the design will mill or print.
When you use more than an intraoral scanner
Full-arch cases can use data from several devices. Each one does a different job in the design.
Face scans
- A face scanner captures the patient's face in 3D.
- SubDesignCenter uses face scans as the esthetic reference, including the facial profile and the anterior teeth.
- That reference guides where the anterior teeth go and how long they are.
- Send a smile scan, a scan with the lips at rest, and a retracted scan that shows the teeth or the existing denture.
- The retracted scan is the shared reference for aligning the face scan with the intraoral or model scans.
- Send face scans as PLY or STL files.
Photogrammetry
- A photogrammetry system measures implant positions from a series of photos, taken with dedicated scan bodies on the implants.
- In the design, photogrammetry is the reference for the implant positions the framework is built on.
- Photogrammetry data holds the implant positions only. It does not show the soft tissue or the opposing arch.
- SubDesignCenter receives photogrammetry data through the device maker's own software.
- Send it with an intraoral or model scan that shows the soft tissue, the bite, a scan of the existing denture or setup, and the implant system on the work ticket.
- That intraoral or model scan is usually taken with scan bodies in place. The scan bodies are the reference for aligning the two files.
Send them as reference scans
You may use devices such as face scanners (for example, RAYFace, MetiSmile or Face Hunter) or photogrammetry systems (for example, PIC system or ICam4D). If you send that data as reference scans with the case, SubDesignCenter uses it alongside the other files during design.
Desktop scans of models, impressions and dentures
- A desktop scanner captures models, impressions, the existing denture or a wax setup in your lab.
- In the design, these scans are the reference for the soft tissue, the existing tooth arrangement and the bite.
- A scan of the existing denture can start the new setup, carrying over tooth positions the patient already uses.
- SubDesignCenter accepts scans from any intraoral or desktop scanner as STL, PLY or OBJ files.
Align the files before you send them
- Each device saves its files in its own coordinate system. To combine them in design software, the files have to be aligned.
- Usually, your lab aligns the files before sending them.
- Align on something captured in both files: the same scan bodies, the same existing denture, or the front teeth visible in a retracted face scan.
- On the work ticket, name the device behind each file.
- Also note which file leads. For example, implant positions come from photogrammetry and the esthetic reference comes from the face scan.
With an intraoral scan, and without one
With an intraoral scan
Send four things:
- Scan-body scans, with the scan bodies captured.
- A scan of the approved setup or the existing prosthesis.
- The bite.
- A work ticket that names the implant system, the final material, your mill or printer, and the stage you are sending.
If you have them, add a soft-tissue scan without scan bodies and a scan of the opposing arch.
SubDesignCenter works from the implant libraries available in 3Shape, so the implant system on the ticket matters. For single implants and custom abutments, see our custom abutment checklist. Labs on 3Shape Communicate can send that way. Otherwise, we set up a case exchange that fits your lab when we start working together.
Without an intraoral scan
SubDesignCenter accepts cases sent only as impression, model and existing denture scans. Your lab scans the case on a desktop scanner:
- Implant positions: scan the model with implant analogs and scan bodies in place.
- Soft tissue: scan the same model again without scan bodies.
- Tooth setup: scan the approved setup, the wax setup or the existing denture, whichever you have.
- Bite: scan the bite record with the models, and scan the models in occlusion.
- Impression only: scan the impression directly, or pour a model and scan that.
The work ticket stays the same, and so do the file formats: STL, PLY or OBJ. For a printable ticket, you can use our free dental lab Rx form and write the stage in its special instructions. What to send at each stage is listed below.
How many stages?
The default plan for SubDesignCenter's All-on-X design service has four stages. This is the usual order. If your lab has a schedule in mind, we adjust the plan to fit it. Each stage follows a schedule agreed for the case.
Stage 1: Diagnostic design
- Diagnostic design is the name of a SubDesignCenter design service. It is a lab deliverable: a design file you use to check the setup in advance.
- You send: an intraoral or model scan that shows the soft tissue, a scan of the existing denture or setup, the bite, a face scan if you have one, and the work ticket.
- You receive: a print-ready design file with the tooth setup.
- Approval point: check the anterior tooth position, length, midline and bite, then approve. The approved setup is the reference for the next stage.
Stage 2: Post-surgery provisional design
- You send: your approval of Stage 1, a scan that captures the implant positions (scan-body scans or photogrammetry data), a soft-tissue scan, the bite, and the implant system on the work ticket.
- You receive: a production-ready provisional design for your mill or printer.
- Approval point: the design goes through our review step before delivery. Your lab checks and approves it before milling or printing.
- If the provisional is adjusted while it is in use, scan it as adjusted. That scan is the reference for Stage 3.
Stage 3: Provisional design after the connection is chosen (MUA and similar)
- You send: a work ticket that names the chosen connection, such as multi-unit abutments (MUA), scan-body scans or photogrammetry data that capture the connection positions, the bite, and a scan of the Stage 2 provisional.
- You receive: a production-ready provisional design for the chosen connection and your mill or printer.
- Approval point: the design goes through our review step before delivery. Your lab checks and approves it before milling or printing.
- If the provisional is adjusted while it is in use, scan it as adjusted. That scan is the reference for Stage 4.
Stage 4: Final prosthesis design
- You send: the scan of the Stage 3 provisional (as adjusted, if it was), scan-body scans or photogrammetry data for the final stage, the bite, and confirmation of the final material.
- You receive: a production-ready final design for your final material and your mill or printer.
- Approval point: the design follows the implant positions captured by your scan bodies and is checked in our review step before delivery, so the framework is built for a predictable, passive fit. A case is not finished until your lab approves it.
Between stages
- Start the next stage only after the current one is approved. This keeps each change inside the stage where it was found.
- Write the stage on every work ticket, so each file is matched to the right stage.
- If something needs to change, request a refinement. The designer adjusts.
Keep patient information to the minimum. The patient's first name and your lab's case number are all SubDesignCenter needs. Leave out last names, dates of birth and contact details. A face scan shows the patient's face, so keep last names and dates of birth out of its file name. Check every file name before you send.
Checklist
- Stages, deliverables and a date for each stage agreed in writing (default four stages: Diagnostic design, post-surgery provisional, provisional after the connection is chosen, final prosthesis)
- Final material and mill or printer named at the start
- Design preferences sent once and confirmed on file
- Devices listed: intraoral scanner, face scanner, photogrammetry, desktop scanner
- Face scans: smile, lips at rest, retracted (PLY or STL)
- Photogrammetry sent through the device maker's software, with an intraoral or model scan that shows the soft tissue and scan bodies
- Files from several devices aligned before sending, with the alignment reference and lead file noted on the work ticket
- With an intraoral scan: scan-body scans, approved setup or existing prosthesis, bite
- Without an intraoral scan: model with and without scan bodies, setup or denture, and bite record, all desktop-scanned
- Work ticket names the implant system, the final material and the stage (and the chosen connection at Stage 3)
- Files: STL, PLY or OBJ for intraoral and desktop scans, PLY or STL for face scans
- Patient first name and lab case number only, and file names checked
- Current stage approved before the next stage starts
Try the file exchange first
If you have not worked with us before, you can check the file exchange on smaller cases first. New labs can send SubDesignCenter three free test cases: crowns, or bridges of up to 3 units, including implant bridges.
If you have questions about your workflow, reach us through the contact section on our site.