Home / News / Dental Model Base Design Outsourcing: What to Send for Die, Implant and QC Models
News

Dental Model Base Design Outsourcing: What to Send for Die, Implant and QC Models

If your lab prints its own models, you can outsource the model design and keep the printing in house. Some details only your lab can decide: which model you need, which printer it goes on, and how the dies are laid out. When they are missing from the ticket, the case turns into questions back and forth, or into fixes after the first print. This guide covers what to decide, what to send and what to check when you outsource dental model base design.

It is written for lab owners and CAD/CAM technicians. It covers files and communication between labs and design services, not clinical decisions.

Step 1: Choose the model type

SubDesignCenter designs print-ready model bases for dies, implant models and quality-control workflows in 3Shape. Each model type needs slightly different files.

  • Die model. A model for crown and bridge work on prepared teeth. It can be a one-piece model, a model with separated dies, or a one-piece model with separate dies. Send the prep, opposing and bite scans.
  • Implant model. A model for implant restorations. For intraoral scans, it can be designed for a digital lab analog, or it can be printed as a one-piece model. Send a scan with the scan bodies captured, and name the implant system on the ticket.
  • QC model. A model your lab uses to seat and check a finished restoration before it ships. Send the same scans used for the restoration design.
  • Every model. Scans can come from any intraoral or desktop scanner as STL, PLY or OBJ files. The work ticket names the model type and your printer.

Step 2: Put what affects the design on the ticket

Tell SubDesignCenter your printer and the model type you need, and we prepare the file for your print workflow. If your lab has set values for any of the points below, add them to the ticket as well. These are general lab practices; you do not need to fill in every one.

  • Printer. Name the printer and its build plate size. They affect the base size and how many models fit on one plate.
  • Resin and print settings. The same file can fit differently on another resin or print setting. If your lab uses set fit clearances for dies and analogs, note them.
  • Base style. Note whether you want a hollow or solid base. For a hollow base, note the wall thickness and where the drain holes go.
  • Die layout. Choose a one-piece model, a model with separated dies, or a one-piece model with separate dies. Note how each die should be trimmed below the margin, too. SubDesignCenter designs the model the way your ticket asks.
  • Implant models. Name the implant system. For intraoral scans, choose a model designed for a digital lab analog and name the analog, or choose a one-piece model. SubDesignCenter designs the implant model the way your ticket asks.
  • Occlusion. Note whether the upper and lower models are used together. If you mount them on an articulator, note how they attach.
  • Base labels. If you label the base, use your lab's case number only.
  • The file you get back. SubDesignCenter returns a print-ready model file, prepared for your printer. If your print software needs a specific file type, note it on the ticket.
  • Patient information. The patient's first name and your lab's case number are all SubDesignCenter needs. Leave out last names, dates of birth and contact details.
  • Case exchange. Labs on 3Shape Communicate can send that way. Otherwise, we set up a case exchange that fits your lab when we start working together.

Need a ticket template? Our free dental lab Rx form runs in your browser and saves as a PDF. Write the model type and printer in its special instructions.

Step 3: Check each design against the same list

These are production checks in your lab, not clinical decisions.

  • Die layout and seating. On screen, check that the model is laid out the way your ticket asked: one piece, separated dies, or one piece with separate dies. On the first print, check that each removable die seats fully and lifts out again.
  • Implant sites. Check that the implant model matches the system and the choice on the ticket. If you use a digital lab analog, check on the first print that it seats fully and does not move.
  • Base and printer. Load the file into your printer software. Check that it fits the build plate without extra edits. For a hollow base, check the wall thickness and drain holes against the ticket.
  • Occlusion. Put the upper and lower models together. Check that they meet in the same position as the bite scan. If the models attach to an articulator, check the attachment against the ticket.
  • Labels. Check that the base shows your case number only.
  • Refinements. If a design needs a change, request a refinement and we adjust it.
  • Turnaround. Note when each case came back. At SubDesignCenter, the standard turnaround for model design is 2 business days. Cases you send in your evening are designed during our working day in Korea, so work starts while your lab is closed.

At SubDesignCenter, every case goes through a review step before delivery, and a case is not finished until your lab approves it. Every case also includes a conversation with the designer about material choice, design decisions and how the design will mill or print. Bring print questions, such as die or analog fit, to that conversation.

Step 4: Send models together with crown or implant designs

  • One set of scans. When the restoration and the model come from the same scans, you can seat the restoration on the model to check it.
  • One ticket. You can add model design to a crown or implant design case. Name the restoration and the model type on the same ticket.
  • Crowns and bridges. For the restoration, send the prep, opposing and bite scans, plus a work ticket with the material. New labs can send SubDesignCenter three free test cases: crowns, or bridges of up to 3 units, including implant bridges. The free test cases do not include model design; ask for it separately.
  • Implant restorations. For custom abutments and screw-retained crowns, send a scan with the scan bodies captured, plus a work ticket naming the implant system.

Model design checklist

  • Model type named: die model, implant model or QC model
  • Printer and build plate size named
  • Fit clearances for dies and analogs, and base style (hollow or solid), noted if your lab has set values
  • Die layout (one piece, separated dies, or one piece with separate dies) and trimming below the margin noted
  • Implant models: system named, digital lab analog or one-piece model chosen, and a scan with scan bodies sent
  • Scans as STL, PLY or OBJ files; for die models, prep, opposing and bite scans
  • Patient first name and lab case number only, and base labels show the case number only
  • Checked: die layout and seating, implant sites, base fits your printer, occlusion
  • Checked: refinements reflected, and the date each case came back

Related reading

Ready to send a model case?

To set up model design for your lab, reach us through the contact section on our site.

Questions

What do I send for model design?

Send the scan file and a work ticket that names the model type and your printer. Scans can come from any intraoral or desktop scanner as STL, PLY or OBJ files.

Which models do you design?

SubDesignCenter designs print-ready model bases for dies, implant models and quality-control workflows in 3Shape. A die model can be one piece, have separated dies, or be one piece with separate dies, as your ticket asks. You receive a print-ready model file, prepared for your printer.

How long does model design take?

Standard turnaround is 2 business days. Cases you send in your evening are designed during our working day in Korea, so work starts while your lab is closed.

3Shape and 3Shape Communicate are trademarks of 3Shape A/S and are mentioned for factual reference only. SubDesignCenter is an independent design service and is not endorsed by 3Shape A/S.

Send a test case.

Your first three test cases (crowns, or bridges of up to 3 units, including implant bridges) are free. Tell us how your lab works and we'll set up a case exchange that fits it.

Start a case consultation →