In an All-on-X case, the final prosthesis design does not start from a blank screen. It starts from the provisional. By the final stage, the provisional may have been worn and adjusted, and the clinic has confirmed it as the starting point for the final. This post covers that step from provisional to final: which files to send, what to write on the work ticket, what comes back, and how to check the final design against the provisional.
It is written for lab owners and CAD/CAM technicians. It covers files and communication between labs and design services, not clinical decisions. For the earlier stages and the devices behind each file, see how to send an All-on-X case for design.
Why the provisional is the reference
- It holds the agreed setup. The clinic has already checked tooth positions, length, midline and bite in the provisional. The final design follows them where the clinic wants them kept.
- It shows what changed. Adjustments made while the provisional was in use exist only on the provisional itself. The earlier design file does not show them. A new scan carries them into the final design.
- The final is built differently. The final material and the way the final is built can differ from the provisional. The final design keeps the agreed setup and is prepared for the final material and your mill or printer.
Record the provisional as it is now
Scan the provisional after its last adjustment. Send:
- The provisional in place, with the bite. An intraoral scan of the provisional in the mouth, the opposing arch, and the bite with the provisional in place. These show the setup and the bite that the final follows.
- The provisional out of the mouth, all the way around. A scan of the removed provisional that includes the fitting surface, the side that faces the soft tissue. If the provisional is in your lab, a desktop scan works too.
- The implant positions for the final. Scan-body scans or photogrammetry data for the final stage, with a soft-tissue scan.
- A face scan with the provisional, if there is one. SubDesignCenter uses face scans as the esthetic reference. Send them as PLY or STL files.
SubDesignCenter accepts scans from any intraoral or desktop scanner as STL, PLY or OBJ files. Photogrammetry data comes to us through the device maker's own software. Labs on 3Shape Communicate can send that way (3Shape Communicate case sharing). Otherwise, we set up a case exchange that fits your lab when we start working together.
What 3Shape describes on the scanning side
- 3Shape's blog post on 360-degree scanning of fixed and removable appliances describes this kind of scan in two ways. It captures several critical pieces of information in a single scan file, and it links the appliance back to the patient's anatomy. The information it lists includes the fitting surfaces. The post names converting a full-arch temporary bridge into the final as the point in full-arch work where these scans are used.
- Since TRIOS & Unite 25.3, TRIOS full-arch implant scanning workflows start from an All-on-X button in the order form (What's New in TRIOS & Unite 25.3). The 26.1 release notes describe one of these workflows with a 360 scan step for the temporary prosthesis (What's New in TRIOS & Unite 26.1).
- In 3Shape's TRIOS guide for one full-arch scan-body system, the provisional is scanned with plenty of surrounding gingiva. Then the opposing arch is scanned, and the bite is scanned with the provisional still in place. After that, the provisional is trimmed from the scan before the scan bodies are scanned (3Shape TRIOS full-arch scan-body guide).
Align the files before you send them
- Usually, your lab aligns the provisional scans with the final scan-body scans before sending.
- Align on areas captured in both scans, such as the soft tissue outside the provisional.
- On the work ticket, note which file leads: the scan-body scans or photogrammetry data for the implant positions, and the provisional scans for the tooth setup.
What to write on the work ticket
- Stage: final prosthesis design.
- Reference: the provisional scans, taken after the last adjustment.
- What stays and what changes: the clinic's notes on what should stay as in the provisional, and any change the clinic asked for.
- Build: the final material and how the final is built, as agreed for the case.
- Connection: the implant system and the chosen connection, such as multi-unit abutments (MUA).
- Production: your mill or printer, and your Dental System version.
- Patient information: the patient's first name and your lab's case number only. Leave out last names, dates of birth and contact details.
Send your design preferences once: contact strength, occlusal clearance, cement gap and minimum thickness. SubDesignCenter keeps them on file and applies them to your lab's cases. Need a ticket template? Our free dental lab Rx form runs in your browser and saves as a PDF.
If SubDesignCenter designed the provisional, we already have that design on file, so you only send the scans of the provisional as it is now. If the provisional was made elsewhere, send the same scans. SubDesignCenter works from a scan of the approved setup or existing prosthesis.
What comes back
- Design files. SubDesignCenter delivers the 3Shape design files themselves, in an editable form, along with production-ready files for your mill or printer. Whether you can open and edit them can depend on your Dental System version.
- Passive fit. The design follows the implant positions captured by your scan bodies and is checked in our review step before delivery, so the framework is built for a predictable, passive fit.
- Consultation. Every case includes a conversation with the designer about the final restoration: material choice, design decisions and how the design will mill or print.
- Schedule. All-on-X stages follow the schedule agreed for each case.
- 3D preview (on request). A 3D preview link is an optional add-on, available on request, so you can check and approve the design in a web viewer on a phone or PC.
- Try-in file. On request, we also send a print-ready file of the final design for a try-in before milling.
Check the final design against the provisional
These are production checks in your lab, not clinical decisions.
- Tooth positions, length, midline and bite match the provisional scans wherever the ticket says they stay.
- Each change on the ticket shows in the design.
- The file is set for the final material and runs in your mill or printer workflow without extra conversion.
- If something needs to change, request a refinement. The designer adjusts. A case is not finished until your lab approves it.
Checklist
- Provisional scanned after its last adjustment
- Provisional in place: intraoral scan, opposing arch, bite
- Provisional out of the mouth, including the fitting surface
- Scan-body scans or photogrammetry data for the final stage, with a soft-tissue scan
- Face scan with the provisional, if there is one (PLY or STL)
- Files aligned before sending, with the lead file for implant positions and for the tooth setup noted
- Ticket: stage, reference, what stays and what changes, final material and build, implant system and connection, mill or printer, Dental System version
- Patient first name and lab case number only
- Final design checked against the provisional scans before approval
Try the file exchange first
If you have not worked with us before, you can check the file exchange on smaller cases first. New labs can send SubDesignCenter three free test cases: crowns, or bridges of up to 3 units, including implant bridges. Our services page lists what to send for each case type.
If you have questions about your workflow, reach us through the contact section on our site.